TM 9-2350-261-10 START ENGINE WITH OUTSIDE POWER SOURCE — Continued 0027 00 8. Run engine on source carrier at a fast idle (1000-1200 RPM) to show charging on BATT GEN indicator. 9. Run engine on source carrier at fast idle for 3-5 minutes before starting disabled vehicle. NOTE In cold weather areas, air box heater can be switched on to heat engine on disabled carrier before attempting to start it. 10. Start engine on disabled carrier (WP 0026 00). WARNING Electric sparking can burn you. Equipment can be damaged. Make sure to disconnect slave cable carefully in order to not cause any sparks. 11. 12. Install cap on auxiliary power receptacle on both carriers. END OF TASK 0027 00-3/4 blank Disconnect slave cable from auxiliary power receptacle on both carriers.