TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download
Page 704 of 832
TM 9-2350-247-20-3 REPLACE NBC ORIFICE CONNECTOR ASSEMBLY AND BRACKET (M548A3) — Continued 0538 00 REMOVAL WARNING NBC agents can kill you. Do not service air cleaner or vent system after NBC attack until carrier has been decontaminated and filters disposed of by NBC team. Unit commander or officer in charge must assign NBC team to decontaminate system and dispose of filters. Unit commander or officer in charge must prescribe necessary protective clothing and safety measures for NBC team. NOTE Procedures to remove, repair, and install orifice connectors and brackets are the same for all five orifice connectors. NOTE Typically, the M548A3 carrier will only have four NBC stations. Converted M730A2 vehicles have five NBC stations. 1. Locate five orifice connectors (1) in carrier. 0538 00-2