TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download
Page 625 of 832
TM 9-2350-247-20-3 REPLACE TACHOMETER CABLE HOUSING AND ADAPTER (M548A3) — Continued 0521 00 2. Insert tachometer cable (4) under driver’s floor plate in carrier. Route through battery compartment bulkhead (5) and into power plant compartment. 3. Place new grommet (6) on tachometer cable (4) at battery compartment bulkhead (5). 4. Place tachometer cable (4) on four weld nuts (7). Secure with four clamps (8), new lock washers (9) and screws (10). 5. Connect tachometer cable (4) to tachometer drive adapter (1) and tachometer (11). FOLLOW-THROUGH STEPS 1. Install driver’s side batteries on left side (WP 0293 00). 2. Connect both battery negative leads (WP 0292 00). 3. Install driver’s floor plate on left side (WP 0395 00). 4. Lower center seat (see your -10). 5. Install instrument panel (WP 0256 00). END OF TASK 0521 00-3/4 blank