TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download
Page 511 of 832
TM 9-2350-247-20-3 REPLACE STOPLIGHT SWITCH (M548A1) — Continued 0493 00 INSTALLATION 1. Install stoplight switch (1) on bottom side of treadle valve assembly floor plate (2) with two new lock nuts (3) and screws (4). 2. Connect circuit lead 75 (5) and circuit lead 75A (6) to stoplight switch (1). 3. Install nipple (7) in stoplight switch (1). Connect air stoplight hose (8) to nipple. 0493 00-3