TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download

Page 400 of 832

TM 9-2350-247-20-3 REPLACE CARGO AREA HEATER FUEL LINES, FITTINGS AND SHIELDS — Continued 0463 00 3. Secure guard (1) to six clamps (2) with six clamps (3), screws (4), washers (5), and new lock nuts (6). WARNING Heat shield insulation may contain asbestos. Inhaled asbestos dust can cause permanent lung damage. Wear a filter mask approved for asbestos protection and rubber gloves during handling of asbestos. Wash skin and clothing with soap and water after handling asbestos. Dispose of asbestos material in accordance with approved hazardous waste disposal procedures. 4. Install shield (7) on cargo cover. Secure with 12 washers (8), 4 screws (9), and new lock nuts (10). 5. Install two unions (11) on fuel pump (12). 6. Install two elbows (13 and 14) in two unions (11). 7. Install new preformed packing (15) and adapter (16) in fuel manifold block (17). 8. Connect fuel tube (18) to adapter (16) and elbow (13). 0463 00-4