TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download
Page 217 of 832
TM 9-2350-247-20-3 REPLACE BILGE PUMP DISCHARGE TUBES AND HOSES (M548A3) — Continued 0426 00 INSTALLATION 1. Install hose (1) and two clamps (2) on adapter (3) and tube (4). Tighten clamps. 2. Install tube (4) on carrier bottom plate with clamp (5), new lock washer (6), and screw (7). 3. Install outlet tube (8) on tube (4) and hose (9) with two clamps (10). 4. Install hose (11) and two clamps (12) on outlet tube (8). 5. Install outlet tube (8) on hull with two clamps (13), new lock washers (14), and screws (15). FOLLOW-THROUGH STEPS 1. Install cab center floor plates and seat support (WP 0395 00). 2. Lower center seat (see your -10). 3. Install hull bottom access cover (WP 0383 00). 4. Connect both battery negative leads (WP 0292 00). END OF TASK 0426 00-3/4 blank