TM-9-2350-247-20-3 Unit Maintenance Manual Volume 3 M548A1 M548A3 Tracked Cargo Carrier Download

Page 169 of 832

TM 9-2350-247-20-3 REPLACE WINCH POWER TAKEOFF CONTROL (M548A1) — Continued 0414 00 INSTALLATION 1. Thread outer control cable (1) through jam nut (2), washer (3), and opening in range selector housing (4). Install jam nut on control cable a few turns but do not tighten. 2. Install new grommet (6) on cab floor. Thread outer control cable (1) through grommet. 3. Install clamp (7), washer (8), and screw (9) to secure outer control cable (1) to bulkhead inside cab. 0414 00-3