TM 9-2350-247-20-2 DRAIN FUEL COMPARTMENT — Continued 0162 00 SERVICING DRAIN NOTE To completely drain fuel compartment, park carrier on a 10 to 50 degree slope or ramp. 1. Place suitable metal container under drain (1) to catch fuel. WARNING Fuel flowing over a metal surface causes static electricity. This will cause a spark and possible fire unless surface is grounded. Provide a metal contact between carrier and container to ensure a ground. 2. Remove drain plug (2) with preformed packing (3). Drain fuel. Discard preformed packing. 3. When fuel is drained, install drain plug (2) with new preformed packing (3). 0162 00-2