TM 9-2350-247-20-2 REPLACE TRANSMISSION SHIFT CONTROL LAMP (M548A3) — Continued 0307 00 INSTALLATION 1. Install new preformed packing (10) on lamp (4). 2. Install lamp (4) into clamp (9). 3. Install filter (5) and shield (6) properly over lamp (4). Secure by tightening screw (7) and nut (8) on clamp (9). 4. Install cover (2) on shift control (3). Secure with two wing screws (1). FOLLOW-THROUGH STEPS 1. Install transmission shift control motor (WP 0306 00). 2. Connect both battery ground leads (WP 0292 00). END OF TASK 0307 00-2