TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download

Page 631 of 1072

TM 9-2350-247-20-2 REPLACE AUXILIARY POWER (SLAVE) RECEPTACLE — Continued 0303 00 INSTALLATION NOTE If the Bendix receptacle is bad, replace it with a NATO auxiliary power receptacle. You will need to order the retaining plate and attaching hardware shown in TM 9-2350-247-24P. NOTE The NATO power receptacle comes with an insulator and gasket. Discard the insulator. The insulator is not required. NOTE Perform Step 1 if the NATO auxiliary power receptacle is installed directly behind the driver’s seat bulkhead (alternate installation). Perform Steps 2 - 3 if the NATO auxiliary power receptacle is mounted on an adapter plate that is installed on the driver’s seat bulkhead. Make sure protective cap retaining cord is attached to receptacle lower mount screw. 0303 00-3 Change 1