TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download

Page 612 of 1072

TM 9-2350-247-20-2 REPLACE BATTERY TO REGULATOR CABLE JACK (M548A3) — Continued 0299 00 INSTALLATION 1. Install battery to regulator cable jack (2) on inside of battery box bulkhead (3). Secure with four new lock nuts (8) and screws (7). 2. Connect battery to regulator plug (1) to battery to regulator cable jack (2) on battery box bulkhead (3). 3. Connect generator to regulator harness connector (6) to jack (2) on battery box bulkhead (3). 4. Connect circuit lead 2 (4) and 2A (5) to positive battery terminal (9) on rear battery (10). Secure with nut (11). 5. Connect circuit 567 lead (1) to bus bar (2). Secure with washer (3), new lock nut (4), and screw (5). 0299 00-4