TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download
Page 585 of 1072
TM 9-2350-247-20-2 REPLACE GENERATOR-TO-REGULATOR WIRING HARNESS (M548A1) 0295 00 THIS WORK PACKAGE COVERS: Removal (page 0295 00-1). Installation (page 0295 00-1). INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0541 00, Item 57) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Battery negative lead(s) disconnected (WP 0292 00) Power plant rear access door removed (see your -10) REMOVAL 1. Disconnect generator-to-regulator connector (1) from generator (2). 2. Disconnect regulator-to-generator connector (3) from regulator (4). 3. Remove generator-to-regulator wiring harness (5) from power plant. INSTALLATION 1. Install generator-to-regulator wiring harness (5) in power plant. 2. Connect generator-to-regulator connector (1) to generator (2). 3. Connect regulator-to-generator connector (3) to regulator (4). 0295 00-1