TM 9-2350-247-20-2 REPLACE GENERATOR FIELD SWITCH — Continued 0288 00 REMOVAL 1. Disconnect circuit 1A and 1B lead plug (1) from generator field switch (2). 2. Remove generator field switch (2) from tee (3). NOTE Earlier switches may have a threaded pipe plug without a head or no plug at all. Discard the pipe plug with the switch. Do not reuse pipe plug because it can be installed too deeply and short out the switch. New switches DO NOT require a pipe plug and washer. 3. Remove plug (4) and washer (5) from side of switch (2). If replacing plug or washer, discard washer. If replacing switch, discard plug and washer with switch. 0288 00-2 Change 1