TM 9-2350-247-20-2 REPLACE STOPLIGHT-TAILLIGHTS — Continued 0278 00 6. Connect circuit 24 lead (12), circuit 22 lead (13), and circuit 21 lead (14) to left stoplight-taillight (3). 7. Connect circuit 23 lead (15) and circuit 22 lead (16) to right stoplight-taillight (3). 8. Install mounting bracket (8) and stoplight-taillight (3) on carrier with four new lock washers (17) and screws (18). FOLLOW-THROUGH STEPS 1. Connect battery negative lead(s) (WP 0292 00). 2. Check stoplight-taillights for proper operation (see your -10). END OF TASK 0278 00-4