TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download
Page 494 of 1072
TM 9-2350-247-20-2 REPLACE BILGE PUMP CIRCUIT BREAKER — Continued 0268 00 INSTALLATION 1. Install circuit breaker (3) on bulkhead with two screws (4) and new lock nuts (5). 2. Connect circuit 450C (2) and 450B (1) to circuit breaker (3). FOLLOW-THROUGH STEPS 1. Install left front battery (WP 0290 00) or (WP 0293 00). 2. Connect battery negative lead(s) (WP 0292 00). 3. Lower center seat (see your -10). 4. Lower driver’s seat (see your -10). END OF TASK 0268 00-2