TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download
Page 442 of 1072
TM 9-2350-247-20-2 REPLACE GENERATOR REGULATOR AND GROUND LEAD (M548A3) — Continued 0251 00 INSTALLATION 1. Attach new lock washer (12) and terminal lead (10) of cable (11) to post (13). Secure with nut (9). 2. Apply sealing compound and sealing compound primer to screws (4). 3. Position regulator (3), clamp (14) and ground lead (7) and secure to bracket (8) with four washers (6), new lock washers (5), and screws (4). 4. Connect power cable (1) and regulator cable (2) to regulator (3). FOLLOW-THROUGH STEPS 1. Connect both battery negative leads (WP 0292 00). 2. Lower center seat (see your -10). END OF TASK 0251 00-2