TM-9-2350-247-20-2 Unit Maintenance Manual Volume 2 M548A1 M548A3 Tracked Cargo Carrier Download

Page 435 of 1072

TM 9-2350-247-20-2 ADJUST GENERATOR-REGULATOR — Continued 0249 00 5. Remove receptacle cap (1) from auxiliary power (slave) receptacle (2). NOTE On carriers that have early model auxiliary power receptacles, touch red lead to positive and black lead to negative sockets in the receptacle. 6. Place red lead(3) in positive socket of plug (4) on late model auxiliary power (slave) receptacle (2). Touch negative lead (5) to outside of plug (2) of late model auxiliary power receptacle. 0249 00-3