TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download

Page 750 of 870

TM 9-2350-247-20-1 REMOVE/INSTALL POWER PLANT (M548A3) — Continued 0131 00 25. Install tow start cable (26) in collar (27). Tighten setscrew (28). 26. Install cable clamp (29), screw (30), washer (31) and nut (32) on tow start cable (26). 27. Push fuel cutoff cable (1) through guide clamp (2) and install in fuel cutoff lever (3). 28. Install collar (4) on fuel cutoff cable (1) and tighten setscrew (5). 29. Tighten screw (6) on guide clamp (2). 0131 00-14