TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download

Page 744 of 870

TM 9-2350-247-20-1 REMOVE/INSTALL POWER PLANT (M548A3) — Continued 0131 00 29. Remove four screws (1), washers (2), and two trunnion caps (3) from hull. WARNING Damaged lifting slings can fall with load. Personnel can be injured or killed. Inspect all slings. Do not use damaged slings. 30. Inspect sling for damage (WP 0443 00). WARNING Lifting sling may slip and allow power plant to drop. Personnel may be injured. Be sure sling is firmly attached and maintains engine support. C A U T I O N Visually monitor power plant clearance at rear bulkhead to avoid damage to components. 31. Attach sling to power plant lifting points, making sure shackle is in hole stamped B. 32. Carefully remove power plant from carrier with hoist and place on blocks. 0131 00-8