TM 9-2350-247-20-1 REMOVE/INSTALL POWER PLANT (M548A1) — Continued 0130 00 17. Remove fuel cutoff cable from power plant. a. Loosen two setscrews (1) that secure control cable (2) in two collars (3) and stop lever (4). b. Remove two screws (5) and lock nuts (6) that secure control cable (2) in clamp (7). Remove cable from power plant. Discard lock nuts. 0130 00-9