TM 9-2350-247-20-1 REMOVE/INSTALL POWER PLANT (M548A1) — Continued 0130 00 NOTE Tag and identify electrical connectors and cables for installation. 4. Disconnect power plant bulkhead connectors. a. Disconnect regulator-to-bulkhead cable connector (3) from bulkhead connector (4). b. Disconnect starter-to-bulkhead cable connector (5) from bulkhead connector (6). c. Disconnect power plant wiring harness connector (7) from bulkhead connector (8). 5. Disconnect differential oil high temperature switch circuit 328 lead (1) at connector (2). 6. Remove vehicle compartment heater duct (WP 0452 00), (WP 0453 00), or (WP 0454 00). 0130 00-3