TM 9-2350-247-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0128 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 55 Semi- Annual (M548A3) Power Plant Mount a. Check mounts and screws for looseness. TIGHTEN LOOSE SCREWS TO 100-120 LB-FT (136-163 N·M) TORQUE. Loose or broken mounts or screws. 56 Semi- Annual (M548A3) Transmission Breather a. Remove transmission breather and check for cracks, dents, and stripped threads. Replace damaged breather. Breather broken or missing. b. Clean transmission breather with cleaning compound. Dry breather and install on transmission. Breather broken or missing. 0128 00-78 Change 1