TM 9-2350-247-20-1 PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS), INCLUDING LUBRICATION INSTRUCTIONS — Continued 0128 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 30 Semi- Annual Track Assembly (T150 Track Only) NOTE The T150 track assembly is to be reversed semi-annually. It needs to be reversed to put wear on the end connectors and track shoe bushings in both directions. NOTE The end connector can only be checked with the track gauge when it is removed from the track shoe pins. NOTE The T150 track assembly needs to be reversed to put wear on the end connectors and track shoe bushings in both directions. This will exend the life of the track. If it is not reversed, the track willl wear unevenly and the life of the track will be reduced. a. Use the track gauge on the inside or facing side of the end connector toward the track shoe when it is removed. The track gauge slot is a no-fit condition. If it does not fit, the end connector is still good for use. When the material on the end connector gets too thin and the track gauge fits, the end connector is bad and needs to be replaced with a new one. 0128 00-44 Change 1