TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download

Page 562 of 870

TM 9-2350-247-20-1 HOOK UP/REMOVE STE/ICE-R FOR ENGINE RPM—Continued 0115 00 C A U T I O N To prevent cable damage, make sure cable is clear of belts and fan blade. 6. Connect cable W4P2 (6) to pulse tachometer (5). 7. Push VTM circuit breaker to ON. 8. Return to troubleshooting task that referred you to this task. REMOVAL 1. Pull VTM circuit breaker to OFF. 2. Disconnect cable W4P2 from pulse tachometer. 3. Remove pulse tachometer from tachometer drive adapter. 4. Install tachometer cable on drive adapter (WP 0520 00 or WP 0521 00). 5. Remove cable W4P1 from jack J2 TK on VTM. 6. Stow transducer cable and pulse tachometer in transit case. 0115 00-2