TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download
Page 538 of 870
TM 9-2350-247-20-1 STE/ICE-R STARTER CIRCUIT TROUBLESHOOTING—Continued 0109 00 2Y 1. Check if starter circuit resistance is within 5 to 27. 2. Is starter circuit resistance within 5 to 27? YES NO GO TO CY (PAGE 0109 00-3) 3Y 1. Check batteries to make sure they are fully charged TM 9-6140-200-14. 2. Verify no faults found. BY 1. Check to see if E013 Is displayed. 2. Is E013 displayed? YES NO BYN 1. Check batteries to make sure they are fully charged TM 9-6140-200-14. 2. Verify no faults found. 2BY 1. Crank engine (see your -10). 2. Does any message appear other than GO? YES NO GO TO DY (PAGE 0109 00-4) 3BY 1. Check how many times E013 has been displayed 2. Is this the third time E013 was displayed? YES NO 3BYN 1. Repeat this part of troubleshooting. 2. Verify no faults found. 4BY 1. Turn off all electrical equipment. 2. Set test select switches to 90. 3. Press and hold test until CAL appears on display. 4. Is offset value within limits of −225 to +225? YES NO 4BYN 1. Go to offset fault isolation TM 9-4910-571-12&P. 2. Verify no faults found. 0109 00-2