TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download
Page 535 of 870
TM 9-2350-247-20-1 STE/ICE-R CHARGING CIRCUIT TROUBLESHOOTING—Continued 0108 00 FIELD CURRENT 1. Install current probe around circuit 1 lead of generator to regulator cable. 2. Point arrow on current probe toward generator. 3. Set test select switches to 01. 4. Press and release test button. 5. When PASS appears, set test select switches to 90. 6. Press and release test button. 7. Raise engine speed to 1000 to 1200 rpm and read rpm display. 8. Stop engine (see your -10). 9. Is current below 6 amps? YES NO CYN 1. Go to charging system malfunctions (WP 0023 00). 2. Verify no faults found. 2CY 1. Check continuity of cables from regulator to generator. 2. If cables are ok, go to charging system malfunctions (WP 0023 00). 3. Verify no faults found. 0108 00-3/4 blank