TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download

Page 515 of 870

TM 9-2350-247-20-1 INTRODUCTION STE/ICE–R (SIMPLIFIED TEST EQUIPMENT FOR INTERNAL COMBUSTION ENGINES-REPROGRAMMABLE) PROCEDURES—Continued 0107 00 E001 A test number which does not exist has been entered on the TEST SELECT switches. E002 The required transducer is not connected. E003 Test number wrong for DCA connected. This can occur if test selected does not apply to the class of vehicle/equipment under test or if the DCA harness does not have the required transducer. E004 No longer used. If message appears turn in test set. E005 Required offset test was not performed. E007 The VID number and number-of-cylinders information entered do not agree. E008 VTM is not receiving required voltage signal for selected test. This message can occur on tests, 14, 15, and 72 thru 79. E009 VTM is not receiving engine speed signal. This applies only to engine power test and SI full power simulation. E010 A wrong VID number was entered. The VTM will only accept numbers between 01 and 99. If E010 is displayed when the VID entered was between 01 and 99, it means that the VID does not agree with the identity of the DCA harness powering the VTM. The VTM will accept this, allowing you to power through the DCA while testing another vehicle. E011 Throttle control was operated incorrectly. It was taking too long to accelerate or decelerate during power test. E012 The SI ignition adapter, TK item 30, or CI pulse tachometer, TK item 34, is missing or is not connected to the VTM. E013 VTM is unable to use data received. E014 The wrong number of cylinders was entered. E015 No longer used. If message appears, turn in test set. E017 VTM is not receiving ignition information during dwell test. E018 Test discontinued due to no information being detected by VTM. This will occur after several minutes of no-signal operation. E020 No first peak information was detected by the VTM. E021 VTM cannot calculate result. Current is over current probe’s range, and VTM did not sample correct portion of data. E022 External voltage was detected in the circuit under test while measuring resistance. E023 VTM’s constant voltage source is not working. E024 Test is not valid for VID entered. E027 Error is entry of compression unbalance constants. E028 Test just entered cannot be used with control function 06. E030 VID entered conflicts with speed transducer attached. E032 Carrier’s cranking speed is varying too much for a compression unbalance measurement. 0107 00-9