TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download
Page 475 of 870
TM 9-2350-247-20-1 TOO MUCH FOREIGN MATTER IN RESERVOIR (M548A1) 0101 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0541 00, Item 57) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) Power plant rear access door removed (see your -10) Center seat raised (see your -10) T 1. Check for restricted air strainer (1) (WP 0500 00). 2. Clean and oil air strainer (1), if contaminated. 3. Is air strainer (1) free of damage? YES NO TN 1. Replace faulty air strainer (WP 0500 00). 2. Verify no faults found. 0101 00-1