TM 9-2350-247-20-1 HI TEMP DIFF OIL INDICATOR MALFUNCTIONS (M548A1)—Continued 0058 00 3DY 1. Remove jumper wire. 2. Install plug on HI TEMP DIFF OIL indicator assembly. 3. Repair power harness circuit 328 (WP 0294 00). 4. Verify no faults found. 0058 00-6