TM 9-2350-247-20-1 BATTERY/GENERATOR INDICATOR MALFUNCTIONS 0052 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Unit T o o l s a n d S p e c i a l T o o l s General Mechanic’s Tool Kit (WP 0541 00, Item 57) STE/ICE-R Test Kit (WP 0541 00, Item 6) Multimeter (WP 0541 00, Item 29) P e r s o n n e l R e q u i r e d Unit Mechanic R e f e r e n c e s See your -10 (WP 0052 00) E q u i p m e n t C o n d i t i o n Engine stopped (see your -10) Carrier blocked (see your -10) NOTE M548A1 and M548A3 troubleshooting procedures are the same. M548A1 procedure is shown. T 1. Remove circuit 27E plug (1) from battery generator indicator jack (2). 2. Remove circuit 10 plug (3) from instrument panel circuit breaker jack (4). 3. Measure resistance between circuit 27E plug (1) and circuit 10 plug (3). 4. Does multimeter read 0 ohms? YES NO TN 1. Repair master power harness circuit 27E (WP 0294 00). 2. Verify no faults found. 0052 00-1