TM 9-2350-247-20-1 NO EXTERIOR LIGHTS OPERATE—Continued 0034 00 Y 1. Remove power/instrument panel wiring harness circuit 10 plug (1) from instrument panel circuit breaker (2). 2. Measure resistance between power/instrument panel wiring harness circuit 15 plug (3) and circuit 10 plug (1). 3. Does multimeter read 0 ohms? YES NO YN 1. Install main wiring harness plug on light switch. 2. Repair power/instrument panel wiring harness circuit 10/15 (WP 0294 00). 3. Verify no faults found. 2Y 1. Install power/instrument panel wiring harness circuit 10 and 15 plugs. 2. Replace light switch (WP 0262 00). 3. Verify no faults found. 0034 00-2