Page 141 of 870

TM 9-2350-247-20-1 ENGINE CRANKS SLOWLY (M548A3)—Continued 0013 00 10Y 1. Inspect electrical lead circuit 6 lead (1) at battery terminal (2). 2. Is lead terminal free from corrosion and damage? YES NO 10YN 1. Repair electrical lead circuit 6 (WP 0294 00). 2. Verify no faults found. 11Y 1. Replace starter (WP 0254 00). 2. Verify no faults found. 0013 00-7/8 blank