TM-9-2350-247-20-1 Unit Maintenance Manual Volume 1 M548A1 M548A3 Tracked Cargo Carrier Download

Page 130 of 870

TM 9-2350-247-20-1 ENGINE CRANKS SLOWLY (M548A1)—Continued 0012 00 Y 1. Measure voltage between starter positive (+) terminal (1) and ground with engine cranking for 3 to 5 seconds. 2. Does multimeter read more than 17 volts? YES NO GO TO CY (PAGE 0012 00-4) 2Y 1. Measure voltage between starter ground (1) and carrier ground with engine cranking for 3 to 5 seconds. 2. Does multimeter read less than 1/2 volt? YES NO 2YN 1. Replace/repair starter ground (WP 0294 00). 2. Verify no faults found. 3Y 1. Replace starter (WP 0253 00). 2. Verify no faults found. 0012 00-2