TM 9-2350-247-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0057 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: WARNING Touching your bare hands or tools to the starter terminals on the starter, or electrical leads when accessing through the bottom access cover, may cause death or serious injury. Do not touch any electrical leads or terminals on the starter because there is 24 volts with over 200 amps connected directly from the batteries. NOTE Access for the front bilge pump on M548A1 is through the center floor plates. Access on the M548A3 is through the bottom hull access cover. e. Check the screen that protects the bilge pump intake. Keep screen and vent hole clean. 0057 00-105 Change 1