TM-9-2350-247-10 Operator Manual M548A1 M548A3 Tracked Cargo Carrier Download
Page 442 of 640
TM 9-2350-247-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0057 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 44 After Fan Belts (Power Plant Compartment) (M548A3) DRIVER a. Check fan belt, generator belt, and coolant pump belts (WP 0068 00). Belt loose, frayed, or missing. Fan assembly grinding or squeaking. b. Inspect idler adjuster for proper adjustment (between operating range marks). Loose or missing idler adjuster and/or hardware. c. Notify unit maintenance if idler is not in operating range and coolant pump belt has more than 3/8 inch deflection between pulleys. 0057 00-74 Change 1