TM-9-2350-247-10 Operator Manual M548A1 M548A3 Tracked Cargo Carrier Download

Page 437 of 640

TM 9-2350-247-10 PREVENTIVE MAINTENANCE CHECKS AND SERVICES — Continued 0057 00 ITEM NO. INTERVAL MAN- HOUR ITEM TO BE CHECKED OR SERVICED CREWMEMBER PROCEDURE EQUIPMENT NOT READY/ AVAILABLE IF: 41 After Personnel Heater Fuel Filter Drain (M548A3) DRIVER a. Remove front cover Any fuel leak. b. Put a suitable container under the drain valve. c. Push on the valve. d. Check that fuel is clear; drain until clear. 0057 00-69 Change 1