TM 9-2350-247-10 TROUBLESHOOTING TABLE — Continued 0056 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator ELECTRICAL SYSTEM MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. NO BATTERY CURRENT. 1. Check if battery cable connectors are loose, disconnected, or corroded. Attach disconnected connectors and tighten loose connectors. If connectors are corroded, notify unit maintenance. 2. Inspect for low water level in battery. If water level is low, notify unit maintenance. 2. BATTERIES DISCHARGED. 1. Check if battery water level is low (WP 0070 00). If water level is low, add distilled water as needed. 2. Using electrical equipment when the engine is not running. Run the engine periodically to recharge the batteries. 3. Check to see if battery cable connectors are loose, disconnected, or corroded. Fix loose, disconnected, or corroded connectors. If connectors are corroded, notify unit maintenance. 4. Check engine generator drive belt. If belt is loose, broken, or missing, notify unit maintenance. 3. WITH MASTER SWITCH ON, INDICATOR LIGHT DOES NOT LIGHT. 1. Lamp may be burned out or there are loose connections in the lamp leads. If battery gauge shows usual readings (WP 0018 00 or WP 0019 00), and other electrical equipment and lights are working, lamp is faulty. You can drive carrier, but be sure to turn MASTER SWITCH OFF when you shut down carrier. Notify unit maintenance of faulty lamp. 2. Check battery indicator gauge to see if batteries are dead. Check for faulty or loose battery connectors. Tighten loose battery cable connectors. If you have to operate carrier with dead batteries, tow start ( WP 005 1 0 0 o r W P 0 052 00 ), or use an o utside pow er source (WP 0015 00) to start the engine. Notify unit maintenance. 0056 00-7/8 blank Change 1