TM 9-2350-247-10 TROUBLESHOOTING TABLE — Continued 0056 00 INITIAL SETUP: M a i n t e n a n c e L e v e l Operator BILGE PUMP MALFUNCTION TEST OR INSPECTION CORRECTIVE ACTION 1. BILGE PUMP DOES NOT WORK WITH THE BILGE PUMP SWITCH ON. 1. Check if MASTER SWITCH is OFF. Turn MASTER SWITCH ON. 2. Check if bilge pump strainer or outlet is clogged. Clean bilge pump strainer or outlet (WP 0073 00). 3. Check if bilge pump vent is blocked. Clean bilge pump vent (WP 0073 00). If you can’t get to the bilge pump to clean it because of a load in the cargo compartment, cycle the bilge pump switch ON and OFF a few times. That usually starts the pump. 0056 00-3/4 blank Change 1