TM-9-2350-247-10 Operator Manual M548A1 M548A3 Tracked Cargo Carrier Download
Page 226 of 640
TM 9-2350-247-10 OPERATE VEHICLE COMPARTMENT AND CARGO HEATER — Continued 0031 00 3. Hold the RUN-OFF-START switch until the indicator light comes on. Then move the switchstraight to RUN without stopping in OFF position. NOTE When using DF-2 fuel, set the HI-LO switch on HI only, and run for 1-3 minutes before switching to LO. 4. Select the high or low heat with the HI-LO switch. The heater will always start on low heat no matter how the HI-LO switch is set, and will go to high after it starts if the switch is at HI. 5. If the heater doesn’t start, try again. If it doesn’t start in three tries, troubleshoot heater (WP 0055 00). 6. Move the RUN-OFF-START switch to OFF to turn the heater OFF. The heater will stop burning right away, but the blower will run until the heater cools off. OPERATE HEAT MANIFOLD CONTROL (M548A1) 1. Move the control handle to the rear stop to direct warm air into the lower cab area. 0031 00-2