TM 9-2350-247-10 START ENGINE WITH EXTERNAL POWER — Continued 0015 00 NOTE Step 5 and Step 6 are for M548A3. 5. Remove cap from auxiliary power receptacle on both carriers. 6. Connect slave cable to receptacle in dead carrier and to receptacle in source carrier. 7. Start engine of source carrier. Make sure engine is running fast enough to show charging on carrier’s battery-generator gauge. NOTE In cold weather, airbox heater of dead carrier can be turned on to heat dead carrier’s engine. See WP 0013 00 or WP 0014 00. 8. Start engine of dead carrier (WP 0013 00) for M548A1 or (WP 0014 00) for M548A3. When engine is running smoothly, disconnect slave cable from receptacle on both carriers. 9. Install cap on auxiliary power receptacle on both carriers. END OF TASK 0015 00-3/4 blank