TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 71 of 176
TM 9-1240-216-34 CHAPTER 3 INSPECTION UPON RECEIPT 3-1. SCOPE This chapter gives procedures to check the M19 and M24 periscopes for faults you can see when they are received in the DS/GS shop. It also tells you what part of this volume to go to for various repairs. A complete inspection should be made and all faults listed on DA Form 2404 before taking any maintenance actions. 3-2. BODY ASSEMBLY INSPECTION UPON RECEIPT TOOLS: 7/16" open end wrench 3/16" flat tip screwdriver 1/4" flat tip screwdriver 1/16" pin open face spanner wrench 1/16" socket head screw key (Allen wrench or equivalent) #2 Phillips SUPPLIES: Cloth (item 1, App A) Grease (item 2, App A) Paint (items 4, 5, App A) Primer (item 6, App A) Solvent (item 9, App A) PERSONNEL: One REFERENCES: JPG 4lC for: Cleaning and lubricating Completing DA Form 2404 TM 43-0139 for painting TM 9-254 for general maintenance TM 10 for removing head assembly (TM 9-2350-215-10 for M60A1, TM 9-2350-257-10 for M60A1 Rise, TM 9-2350-260-10 for M60, and TM 9-2350-222-10 for M728) EQUIPMENT CONDTION: Body assembly on work bench; power disconnected PRELIMINARY PROCEDURES: Remove head assembly (TM 10) Handle lenses with care. Do not put fingerprints on them. Do not place on rough surfaces. Clean after inspection. NOTE One body assembly configuration will be pictured for use with inspection procedure. Vol II Para 3-1 3-1