TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download

Page 59 of 176

TM 9-1240-216-34 B-2. ASSEMBLY (CONT) FRAME 2 Step 1. 2. 3. 4. Procedure Connect (-) black lead alligator clip (1) to any bare place on high voltage power supply (2). Connect (+) red lead alligator clip (3) to center pin (4) of high voltage power supply input connector (5) without touching body (6). Turn on 0-36 VDC power supply. In the next step, if the current starts to go over 1 ampere, immediately set the voltage to zero. Turn off 0-36 VDC power supply and tell your supervisor. While watching both the voltmeter (7) and current meter (8), slowly raise voltage to 24V. END OF TASK Para B-2 Cont Vol I B-3/(B-4 blank)