TM 9-1240-216-34 APPENDIX B ASSEMBLY OF POWER SUPPLIES B-1. SCOPE M 19 or M24 series periscopes. B-2. ASSEMBLY This appendix tells how to connect the 0-36 VDC power supply and the high voltage power supply to the TEST EQUIPMENT: High voltage power supply (16,000 VDC) (taken from tank) 0-36 VDC power supply Multimeter test leads High voltage cable WARNING The high voltage power supply puts out 16,000 VDC as soon as input power is applied. There is no on/off switch. NOTE Do not connect 24V input power to the high voltage power supply until after its output is connected to the periscope. The high voltage cable is used to connect the high voltage power supply output to the periscope. Both cable end connectors are identical, so either end of the cable may go to either connector. The high voltage power supply connectors are not labeled, but are different sizes. The high voltage connector will fit only the connector providing the high voltage output. Vol I Para B-1 B-1