TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 44 of 176
TM 9-1240-216-34 4-5. NO IMAGE OR DIM IMAGE OR POOR FOCUS IN EITHER EYEPIECE (SHEET 1 OF 10) APPLICABLE CONFIGURATIONS: M19 and M24 new configurations TEST EQUIPMENT: Multimeter PERSONNEL: One REFERENCES: JPG 4lC for use of multimeter TM 10 for removing head assembly (TM 9-2350-215-10 for M60Al, TM 9-2350-257-10 for M60Al Rise, TM 9-2350-260-10 for M60, and TM 9-2350-222-10 for M728) EQUIPMENT CONDITION: Body assembly on work bench; power disconnected PRELIMINARY PROCEDURES: Remove head assembly (TM 10) NOTE This procedure is for the M19 and the M24 new configuration periscopes. The M24 new configuration is pictured. , Para 4-5 (Sheet 1 of 10) 4-16 Vol I