TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download

Page 40 of 176

TM 9-1240-216-34 4-4. IMAGE DIM OR FLICKERING (SHEET 1 OF 4) APPLICABLE CONFIGURATIONS: M19 and M24 old configurations TEST EQUIPMENT High voltage power supply (tank) Multimeter 0-36 VDC power supply High voltage cable PERSONNEL: One REFERENCES: JPG 41C for: Using 0-36 VDC power supply Using multimeter EQUIPMENT CONDITION: Body assembly on work bench with head assembly installed; power disconnected PRELIMINARY PROCEDURES: Assemble power supplies (APP B) NOTE This procedure is for both the M19 and M24 periscopes. The M24 is pictured. Para 4-4 (Sheet 1 of 4) 4-12 Vol I