TM 9-1240-216-34 4-2. NO IMAGE (IN ONE OR BOTH EYEPIECES) WHEN POWER SUPPLY IS ON (SHEET 3 OF 5) YOU NEED TO REMOVE TERMINAL HOUSING (1) ONLY ON THE SIDE WHERE THE IMAGE CAN NOT BE SEEN REMOVE TERMINAL HOUSING (1) (VOL II, PARA 4-17) USING MULTIMETER CHECK THE RESISTANCE BETWEEN TERMINAL CONNECTOR (2) OF BOARD ASSEMBLY (3) TO CENTER LEG TEE (4) OF HIGH VOLTAGE CABLE ASSEMBLY (5) (JPG) ZERO OHMS REPLACE HIGH VOLTAGE CABLE ASSEMBLY (5) (VOL II, PARA 4-19) Vol I Para 4-2 (Sheet 3 of 5) 4-3