TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download

Page 128 of 176

TM 9-1240-216-34 4-24. RECEPTACLE INSTALLATION TOOLS: 3/16" flat tip screwdriver Hydraulic sealing gun (with adapter) SUPPLIES: Sealing compound (item 7, App A) Dry cleaning solvent (item 9 App A) Cleaning cloth (item 1, App A) PERSONNEL: One REFERENCES: JPG 4lC for sealing EQUIPMENT CONDITION: Body assembly on work bench; power disconnected FRAME 1 Step 1. 2. 3. 4. 5. 6. Procedure Dry cleaning solvent can catch on fire. Keep it and all material that can catch on fire away from flames. Use only in a room with a lot of fresh air. Using cloth dampened with dry cleaning solvent, remove all old sealing compound from receptacle (1) and receptacle hole in body assembly (2). Install preformed packing (O-ring) (3) in groove in receptacle hole of body assembly (2), Install and position receptacle (1) into body assembly (2). Install receptacle cap (4) on receptacle (1). NOTE In step 5, three of the four lockwashers and screws hold cap chains (5). Using screwdriver, install three chains (5), four lockwashers (6), and four screws (7). Using sealing gun with adapter, force sealing compound in receptacle sealing hole (8) in body assembly (2) until receptacle (1) is completely sealed (JPG). WARNING Para 4-24 4-44 Vol II