TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download

Page 126 of 176

TM 9-1240-216-34 Section 7. RECEPTACLE 4-22. RECEPTACLE MAINTENANCE PROCEDURES INDEX Task Reference (para) Removal 4-23 Installation 4-24 4-23. RECEPTACLE REMOVAL TOOLS: 3/16" flat tip screwdriver PERSONNEL: One EQUIPMENT CONDITION: Body assembly on work bench; power disconnected PRELIMINARY PROCEDURES: Remove cover assembly (para 4-14 ) FRAME 1 Step Procedure 1. 2. 3. 4. 5. Using screwdriver, remove four screws (1), four lockwashers (2), and three chains (3) from receptacle (4) and body assembly (5). Unscrew and remove receptacle cap (6). Using your hand, turn receptacle (4) slightly from side to side and pull until receptacle (4) is out of body assembly (5). Remove preformed packing (O-ring) (7) from groove in hole in body assembly (5) where receptacle (4) was removed. Using your fingers, from inside of body assembly (5) pull high voltage cable (8) in through hole (9). END OF TASK Para 4-22 4-42 Vol II