TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 122 of 176
TM 9-1240-216-34 4-21. HIGH VOLTAGE CABLE ASSEMBLY INSTALLATION TOOLS: 3/16" flat tip screwdriver SUPPLIES: Electrical insulating compound (item 2, App A ) PERSONNEL: One REFERENCES: JPG 4lC for application of eletrical insulating compound EQUIPMENT CONDITION: Body assembly on work bench; power disconneted NOTE Frame 1 is for M19 and M24 new configurations. Frame 2 is for M19 and M24 old configurations. FRAME 1 Step 1. 2. Procedure Put a thin coat of electrical insulating compound on center leg (1) of cable assembly (2) (JPG). Put center leg (1) of cable assembly (2) in receptacle (3) until shoulder on center leg touches receptacle (3). NOTE FOLLOW-ON MAINTENANCE Install both terminal board assemblies (para 4-18, frame 1 only). Do checkout procedure (Vol I, para 2-2). END OF TASK Para 4-21 4-38 Vol II