TM-9-1240-216-34 Maintenance Manual M19 and M24 Persicope Download
Page 118 of 176
TM 9-1240-216-34 Section 6. HIGH VOLTAGE CABLE ASSEMBLY 4-19. HIGH VOLTAGE CABLE ASSEMBLY MAINTENANCE PROCEDURES INDEX Step Reference (para) Removal 4-20 Installation 4-21 4-20. HIGH VOLTAGE CABLE ASSEMBLY REMOVAL TOOLS: 3/16" flat tip screwdriver PERSONNEL: One EQUIPMENT CONDITION: Body assembly on work bench with head assembly removed: power supply disconnected PRELIMINARY PROCEDURES: Remove cover assembly (para 4-13) Remove terminal board assembly on each side of body assembly (para 4-17) (M 19 and M24 new configurations only) NOTE Frame 1 is for M19 and M24 old configurations, Frame 2 is for M19 and M24 new configurations. FRAME 1 Step 1. 2. 3. 4. 5. 6. 7. 8. Procedure Using screwdriver, unscrew long screw (1) and short screw (2) until clear of body assembly (3), Do not remove. Lift terminal housing (4) from body assembly (3). Remove short screw (2) and lockwasher (5) from terminal housing (4). Remove long screw (1) slowly and remove spacer (6), ground wire and lockwasher (7). Hold board assembly (8) and slide terminal housing (4) off. Using screwdriver, remove screw (9), lockwasher (10), and cable terminal A from terminal (11) of board assembly (8). Unscrew receptacle cap (12). Do steps 1 thru 6 again to disconnect cable terminal B of cable assembly (13) from terminal housing (14) on both sides of body assembly (3). Para 4-19 4-34 Vol II